The
AS200 Wireless Alarm, Monitoring and Data Logging
System allows laboratory and hospital equipment such
as Liquid Nitrogen, ULT Freezers, Fridges, Freezers
and Incubators to be alarmed, monitored and data
logged. The temperature transmitter range is
-200°C to +100°C with an accuracy of 0.1°C.
The system is an enhancement on the reliable and
trusted previous
wireless alarm system currently in 24 hour service
protecting valuable product in LN2 vessels and
refrigerated storage throughout the UK .
The system ensures the safety and continued
effectiveness of medicines, blood products and
samples required to be held at specific
refrigeration and freezer temperatures. Due to the
high value of many of these goods, QA programs
increasingly require that storage temperatures are
to be verified several times per day and that
records be maintained. The AS200 System will meet
the alarm, monitoring and logging requirements,
offering different levels of monitoring, data
capture and analysis software.
Various levels of communications can be fitted to
the receiver
unit, from a conventional
auto-dialler to a GSM dialler or web enabled
facility. The GSM dialler and web enabled
facility will give the target recipients details of
the alarming equipment . The web enabled
facility can contact up to 10 mobile phones sending
a message with details of equipment in alarm.
Traceable calibration for temperature can be carried
out for the AS200TX alarm transmitters.
 |
Wireless alarm and data logging with
minimal installation disruption.
|
 |
Independent alarm system with up to
999 alarms and acknowledgements
stored in the receiver event log.
|
 |
Selective communications to suit
requirements.
|
 |
Receiver connection to a computer
enabling full monitoring and logging
facilities.
|
 |
Up to
4 alarm acknowledgement key-fobs,
details of acknowledger kept in
event log.
|
 |
Temperature transmitter range -200°C
to +100°C.
|
 |
Transmitter accuracy 0.1°C over
entire range.
|
 |
Range
500m uninterrupted signal path.
|
 |
Temperature, time delay, transmitter
ID and high & low alarms displayed
on transmitter.
|
 |
Full
local alarming :- visual and audible
at both transmitter equipment end
and receiver.
|
 |
High,
low, power fail, door open and volt
free alarms on the transmitter.
|
 |
Reactivation of alarm every 60
minutes if transmitter at equipment
end has not been muted. (This
feature can be disabled by
client
)
|
 |
Standard receiver has 125 channels,
one transmitter per channel.
|
 |
Download software enables the
creation of an audit trail from the
alarm and acknowledgement event log.
|
 |
Easy
to use monitoring, data capture and
analysis software giving numerical,
graphical and statistical
information
|