AS200 SYSTEM OVERVIEW
AS200 System Overview

 

The AS200 Wireless Alarm, Monitoring and Data Logging System allows laboratory and hospital equipment such as Liquid Nitrogen, ULT Freezers, Fridges, Freezers and Incubators to be alarmed, monitored and data logged.  The temperature transmitter range is -200°C to +100°C with an accuracy of 0.1°C.  The system is an enhancement on the reliable and trusted previous wireless alarm system currently in 24 hour service protecting valuable product in LN2 vessels and refrigerated storage throughout the UK .

The system ensures the safety and continued effectiveness of medicines, blood products and samples required to be held at specific refrigeration and freezer temperatures. Due to the high value of many of these goods, QA programs increasingly require that storage temperatures are to be verified several times per day and that records be maintained. The AS200 System will meet the alarm, monitoring and logging requirements, offering different levels of monitoring, data capture and analysis software.

Various levels of communications can be fitted to the receiver unit, from a conventional auto-dialler to a GSM dialler or web enabled facility.  The GSM dialler and web enabled facility will give the target recipients details of the alarming equipment .  The web enabled facility can contact up to 10 mobile phones sending a message with details of equipment in alarm.

Traceable calibration for temperature can be carried out for the AS200TX alarm transmitters. 

bullet
Wireless alarm and data logging with minimal installation disruption.
bullet
Independent alarm system with up to 999 alarms and acknowledgements stored in the receiver event log.
bullet
Selective communications to suit requirements.
bullet
Receiver connection to a computer enabling full monitoring and logging facilities.
bullet
Up to 4 alarm acknowledgement key-fobs, details of acknowledger kept in event log.
bullet
Temperature transmitter range -200°C to +100°C.
bullet
Transmitter accuracy 0.1°C over entire range.
bullet
Range 500m uninterrupted signal path.
bullet
Temperature, time delay, transmitter ID and high & low alarms displayed on transmitter.
bullet
Full local alarming :- visual and audible at both transmitter equipment end and receiver.
bullet
High, low, power fail, door open and volt free alarms on the transmitter.
bullet
Reactivation of alarm every 60 minutes if transmitter at equipment end has not been muted. (This feature can be disabled by client )
bullet
Standard receiver has 125 channels, one transmitter per channel.
bullet
Download software enables the creation of an audit trail from the alarm and acknowledgement event log.
bullet
Easy to use monitoring, data capture and analysis software giving numerical, graphical and statistical  information
 
 